878769-001 - Redundant Fan Cage Kit with 4 Hot-Plug Fan Modules for HPE ProLiant ML350 Gen10 G10 Server
Add advanced cooling and redundant hot-plug airflow support to your ML350 Gen10 server with this redundant fan cage kit. This assembly is used in supported ProLiant ML350 Gen10 configurations that require the additional front fan cage and four hot-plug fan modules for improved thermal performance. It is commonly used in heavier system builds such as dual-processor configurations, rack-converted systems, storage-dense chassis, NVMe-enabled setups, and other higher-demand server environments.
Technical Specifications
- Kit part number: 878769-001
- Related option kit number: 874572-B21
- Related fan cage assembly numbers: 879443-001, 879984-001
- Server platform: ProLiant ML350 Gen10
- Kit type: Redundant fan cage kit
- Configuration: 1 fan cage assembly with 4 hot-plug fan modules
- Fan module spare number: 879151-001
- Additional fan label numbers seen on installed modules: 879814-001, 867626-001
- Fan manufacturers by production batch: Sunon or Delta Electronics
- Sunon fan model: PF92381BX-Q110-099
- Delta fan model: PFR0912XHE
- Fan electrical rating: 12V DC
- Connector type: 4-pin / 4-wire
- Cooling style: Hot-plug redundant chassis cooling fan assembly
Interchangeable / Replacement Part Numbers
-
878769-001, 874572-B21, 879443-001, 879984-001, 879151-001, 879814-001, 867626-001, PF92381BX-Q110-099, PFR0912XHE
✅ Confirmed Compatibility
Please note that the following list is not exhaustive. Compatibility depends on your system's specific configuration. It's essential to verify compatibility with your system or enclosure manufacturer prior to installation.
✔️ ProLiant ML350 Gen10: Tower systems using the redundant hot-plug fan cage configuration
✔️ ProLiant ML350 Gen10: Rack conversion systems requiring the redundant fan kit
✔️ ProLiant ML350 Gen10: Dual-processor configurations requiring advanced cooling support
✔️ ProLiant ML350 Gen10: 24 SFF storage configurations
✔️ ProLiant ML350 Gen10: 12 LFF storage configurations
✔️ ProLiant ML350 Gen10: NVMe Express Bay upgrade configurations
✔️ ProLiant ML350 Gen10: Fully populated front storage bay configurations
✔️ ProLiant ML350 Gen10: Higher-demand builds using expanded storage, risers, and other performance-oriented options that require the redundant fan cage
☑️ Key Features
- Complete redundant cooling fan cage kit for ProLiant ML350 Gen10
- Includes 4 hot-plug fan modules installed in the fan cage assembly
- Supports advanced cooling for higher-load server configurations
- Designed for ML350 Gen10 systems that require the optional redundant fan kit
- Helps maintain proper airflow across processors, memory, storage, and expansion areas
- Hot-plug fan design supports easier serviceability in compatible systems
- Fan module manufacturer may vary between Sunon and Delta Electronics depending on batch
- Ideal for replacing a missing, damaged, or failed redundant fan cage assembly
⚙️ Fit Notes
- This listing is for the complete fan cage kit with 4 installed fan modules
- This is not a single loose fan only
- Individual installed fan modules may carry labels such as 879151-001, 879814-001, or 867626-001
- This kit is intended for ProLiant ML350 Gen10 systems only
- Please verify your server is configured for or requires the redundant fan cage setup
- Fan manufacturer label may vary between Sunon PF92381BX-Q110-099 and Delta PFR0912XHE
- Designed for systems that use the hot-plug redundant cooling assembly, not the standard rear-fan-only configuration