false

530762-003 - SPS-CORD,C13-C14,JUMPER,6FT,DATA,SPL

Item#: 530762-003 Condition: Refurbished
On Sale $229.00
Retail $349.00
In Stock
Usually Ships in 2-3 Business Days
Money Back Guarantee
Not satisfied? Send it back!
Request a quote below to see price
REQUEST A QUOTE

530762-003 - SPS-CORD,C13-C14,JUMPER,6FT,DATA,SPL

Item#: 530762-003

* Indicates a required field

  • Product Description
  • Compatible Models
Product Description

573696-001 - 6 FT IEC C14 to C13 10A 250V Intelligent PDU PLC Power Cord

This 6-foot rack power jumper delivers AC power while supporting Intelligent Power Discovery through integrated Power Line Communications. Its bright-blue IEC connector housings distinguish it from ordinary power-only C13-to-C14 cables.

The cable also functions as a standard IEC power jumper when connected to compatible equipment that does not support Power Discovery.

Technical Specifications

  • Part Number: 573696-001
  • Product Type: Intelligent rack PDU power-and-data communications cable
  • Source Connector: IEC 60320 C14 male
  • Equipment Connector: IEC 60320 C13 female
  • Length: 6 ft / approximately 1.83m
  • Maximum Current: 10A
  • Maximum Voltage: 250V AC
  • Communication Technology: Intelligent Power Discovery / Power Line Communications
  • Connector Identification: Bright-blue IEC connector housings
  • Cable Color: Black with blue connector housings
  • Connector Orientation: Straight molded ends
  • Grounding: Three-pole grounded IEC connection
  • Package Quantity: One cable
  • Wall Plug: None; designed for a rack PDU or UPS connection
  • Connection Path: C14 male end connects to an IEC C13 PDU or UPS outlet; C13 female end connects to equipment with an IEC C14 inlet

Interchangeable / Replacement Part Numbers

573696-001, 530762-003, SG510A

✅ Confirmed Compatibility

Compatibility is determined by the installed power-supply inlet and source receptacle. The equipment must have an IEC C14 inlet, the PDU or UPS must provide an IEC C13 outlet, and the operating load must not exceed 10A at 250V. Power Discovery requires a compatible intelligent PDU and PLC-enabled power supply. Other qualifying equipment uses this cable for power only.

Power Discovery / PLC Compatibility

✔️ Power Discovery Infrastructure: Intelligent Power Distribution Units, Intelligent Modular Extension Bars, Common Slot Platinum and Platinum Plus power supplies, and Flex Slot Titanium or Platinum Plus supplies equipped with a blue PLC-ready IEC C14 inlet
✔️ ProLiant G6 and G7 Rack Servers: DL160 G6, DL165 G7, DL170h G6, DL180 G6, DL360 G6, DL360 G7, DL380 G6, DL380 G7, DL385 G6, DL385 G7, DL580 G7, DL585 G7, DL980 G7 when configured with a supported Common Slot Platinum AC supply
✔️ ProLiant G6 and G7 Tower Servers: ML330 G6, ML350 G6, ML350 G7, ML370 G6 when configured with a supported Common Slot Platinum AC supply
✔️ ProLiant G6 and G7 Scale-Out Servers: SL160s G6, SL160z G6, SL165s G7, SL165z G6, SL165z G7, SL170s G6, SL390s G7, SL4545 G7 with the applicable Common Slot supply
✔️ ProLiant Gen8 Rack Servers: DL160 Gen8, DL320e Gen8, DL320e Gen8 v2, DL360e Gen8, DL360p Gen8, DL380e Gen8, DL380p Gen8, DL385p Gen8, DL388p Gen8, DL560 Gen8, DL580 Gen8
✔️ ProLiant Gen8 Tower Servers: ML310e Gen8, ML310e Gen8 v2, ML350e Gen8, ML350p Gen8
✔️ ProLiant Gen8 Scale-Out Servers: SL210t Gen8, SL230s Gen8, SL250s Gen8, SL4540 Gen8
✔️ ProLiant Gen9 Power Discovery Systems: DL360 Gen9, DL380 Gen9 and ML350 Gen9 when fitted with a PLC-enabled Flex Slot Titanium or Platinum Plus AC supply
✔️ Network CLIM Systems: NonStop i R5 5C IP CLIM CM881R5, NonStop i R5 CG 5C IP CLIM CM881R5CG, NonStop AC Gen8 4C/1C IP CLIM G9Q31A, NonStop X AC v2 4C/1C IP CLIM G9Q31B
✔️ Storage CLIM Systems: NonStop i R5 Storage CLIM CM871R5, NonStop AC Gen8 Storage CLIM G9Q35A, NonStop X AC v2 Storage CLIM G9Q35B
✔️ ConvergedSystem 700 Components: CS 700 Management Block 751867-B21, CS 700 5920 Switch Block 751868-B21, CS 700 5120 Switch Block 751869-B21, ConvergedSystem 700 for Virtualization 1.1 Management Block G9E99A

Standard Power-Only Compatibility

The following systems are compatible only when equipped with an IEC C14 AC inlet and when their actual input current does not exceed 10A. Power Discovery is not available unless the installed supply also supports PLC.

✔️ Additional ProLiant Gen9 Systems: DL20 Gen9, DL60 Gen9, DL80 Gen9, DL120 Gen9, DL160 Gen9, DL180 Gen9, DL388 Gen9, DL560 Gen9, DL580 Gen9, ML10 v2, ML30 Gen9, ML110 Gen9, ML150 Gen9
✔️ ProLiant Gen10 and Gen10 Plus Systems: DL20, DL160, DL180, DL325, DL345, DL360, DL365, DL380, DL385, DL560, DL580, ML30, ML110 and ML350 series
✔️ ProLiant Gen11 Systems: DL20, DL110, DL145, DL320, DL325, DL345, DL360, DL365, DL380, DL385, DL560, ML30, ML110 and ML350 series
✔️ Apollo and Dense Compute Systems: Apollo 4200 Gen9, Apollo 4510 Gen9, XL290n Gen10 and qualifying nodes with a dedicated IEC C14 inlet
✔️ StoreEasy 1000-Series: StoreEasy 1430, 1440, 1450, 1530, 1540, 1550, 1630, 1640, 1650, 1830, 1840, 1850
✔️ StoreVirtual Systems: StoreVirtual 4130, 4330, 4530, 4630, 4730
✔️ MSA and Modular Smart Array Systems: P2000 G3, MSA 1040, MSA 2040, MSA 2042, MSA 2050, MSA 2052, MSA 1060, MSA 2060, MSA 2062 and matching AC drive enclosures
✔️ D-Series Disk Enclosures: D2600, D2700, D3600, D3610, D3700, D3710, D6020
✔️ 3PAR StoreServ Systems: StoreServ 7200, 7400, 7450, 8200, 8400, 8440 and 8450 controller nodes and qualifying drive enclosures
✔️ PowerEdge 11th Generation Servers: R210, R210 II, R310, R410, R415, R510, R515, R610, R710, R715, R810, R815, T110, T110 II, T310, T410, T610, T710
✔️ PowerEdge 12th Generation Servers: R220, R320, R420, R520, R620, R720, R720xd, R820, T320, T420, T620
✔️ PowerEdge 13th Generation Servers: R230, R330, R430, R530, R630, R730, R730xd, R830, R930, T130, T330, T430, T630
✔️ PowerEdge 14th Generation Servers: R240, R340, R440, R540, R640, R6415, R740, R740xd, R740xd2, R7415, R7425, R840, R940, R940xa, T140, T340, T440, T640
✔️ PowerEdge 15th and 16th Generation Servers: R250, R350, R450, R550, R650, R650xs, R6515, R6525, R750, R750xa, R750xs, R7515, R7525, R660, R6615, R6625, R760, R760xa, R7615, R7625, T150, T350, T360, T550, T560
✔️ PowerVault Storage: MD1200, MD1220, MD3200, MD3220, MD3400, MD3420, MD3600f, MD3620f, MD3800f, MD3820f, ME4012, ME4024, ME4084, ME412, ME424, ME484, NX3230, NX3340, NX440
✔️ ThinkSystem Rack Servers: SR250, SR530, SR550, SR570, SR590, SR630, SR635, SR645, SR650, SR655, SR665, SR850, SR850P, SR860, SR950 and qualifying V2 or V3 configurations
✔️ ThinkSystem Tower Servers: ST250, ST550, ST650 and qualifying V2 or V3 configurations
✔️ System x Servers: x3250 M4, x3250 M5, x3250 M6, x3300 M4, x3500 M4, x3500 M5, x3530 M4, x3550 M4, x3550 M5, x3630 M4, x3650 M4, x3650 M5, x3750 M4, x3850 X6, x3950 X6
✔️ UCS Rack and Storage Servers: UCS C220 M3 through M7, UCS C240 M3 through M7, UCS C480 M5 and UCS S3260 configurations with an IEC C14-input AC supply
✔️ Nexus Networking Systems: Nexus 3000, 5000, 5500, 5600, 6000, 7000 and 9000 Series switches with an IEC C14-input supply
✔️ PowerSwitch Networking Systems: N1500, N2000, N3000, N4000, S3000, S4000, S5000, S6000, Z9000, Z9100-ON, Z9264F-ON, Z9332F-ON
✔️ Aruba and ProCurve Networking Systems: 2920, 2930M, 3800, 3810M, 5400R zl2, 8200zl, 8320, 8325, 8360, 8400 and 9300 Series
✔️ FlexNetwork Switching Systems: 5120, 5130, 5140, 5510, 5520, 5710, 5800, 5820X, 5900, 5920, 5940, 5950, 7500, 7900 and 10500 Series
✔️ Supermicro Rack Chassis: SC113, SC116, SC213, SC216, SC217, SC815, SC816, SC819, SC825, SC826, SC827, SC835, SC836, SC846 and SC847 configurations with IEC C14-input supplies
✔️ General IEC Equipment: Rack servers, disk arrays, network switches, KVM consoles, monitors, workstations, appliances and other equipment with a standard IEC C14 inlet and a maximum input current of 10A or less

☑️ Key Features

☑️ 6-foot intelligent rack PDU jumper
☑️ IEC C14 male to IEC C13 female connection
☑️ Rated for up to 10A and 250V AC
☑️ Supports Intelligent Power Discovery and Power Line Communications
☑️ Bright-blue connectors identify the PLC-enabled cable
☑️ Also provides standard AC power to qualifying non-PLC equipment
☑️ Straight molded connectors for organized rack installations
☑️ Grounded three-pole construction

⚙️ Fit Notes

  • This is a rack PDU jumper and does not have a NEMA wall plug.
  • The C14 male end connects to an IEC C13 PDU or UPS outlet. The C13 female end connects to the equipment’s IEC C14 inlet.
  • The cable does not convert voltage. Confirm that the source voltage is supported by the connected equipment.
  • Power Discovery requires a compatible intelligent PDU or extension bar and a PLC-enabled power supply.
  • Standard C13-to-C14 cables can deliver power but cannot replace this cable’s data-discovery functionality.
  • Do not exceed 10A. Some 1200W and higher supplies may exceed 10A when operated at 100–120V.
  • Equipment with IEC C16, C20, C22, DC, hardwired or other power inputs requires a different cable.
  • One cable is required for each powered PSU inlet. Redundant systems normally require two cables.
  • This listing is for one cable. SG511A is a five-cable bundle and is not the same sale quantity.
  • Some catalogs round assembly number 530762-003 to 2m or 6.5 ft. The official 573696-001 and SG510A specification is approximately 1.8–1.83m or 6 ft.
Compatible Models

Product Reviews

Purchased This Product Before? Write a Review

Free Ground Shipping

On Orders $99 or more

Money Back Guarantee

Not Satisfied? Return it!

Hassle-Free Returns

Shop with confidence

Need Assistance?

Call 786-449-6211 or Email Us