Product Description

IC695RMX128-EG - 128MB Multi Mode Fiber Redundancy Memory Xchange Module for GE Fanuc PACSystems RX3i

The IC695RMX128-EG is a GE Fanuc / Emerson PACSystems RX3i Redundancy Memory Xchange module designed for high-speed reflective memory communication and RX3i Hot Standby CPU redundancy applications. This module provides 128 MB of reflective memory and uses multi mode fiber connectivity for fast data transfer between compatible RX3i controllers or reflective memory network nodes.

This module is commonly used in RX3i redundant control systems where a dedicated fiber-optic communication link is required between the primary and secondary controller systems. It may also be used as a reflective memory node in supported high-speed memory exchange network applications when properly configured.

Technical Specifications

  • Part Number: IC695RMX128-EG
  • Base Catalog Number: IC695RMX128
  • Product Type: Redundancy Memory Xchange Module
  • Series: PACSystems RX3i
  • Module Family: RX3i RMX / Redundancy Memory Xchange
  • Memory Capacity: 128 MB
  • Memory Type: Reflective memory
  • Fiber Type: Multi Mode Fiber
  • Network Type: High-speed reflective memory / redundancy fiber-optic network
  • Communication Rate: 2.12 Gbaud
  • Connector Type: Dual LC fiber-optic ports
  • Fiber Port Markings: TX Front / RX Back
  • Slot Width: Single-slot RX3i module
  • Installation Location: RX3i main rack
  • Backplane Requirement: RX3i Universal Backplane / PCI backplane environment
  • Maximum Reflective Memory Nodes: Up to 256 nodes in supported reflective memory network configurations
  • Supported Use: Reflective memory node or dedicated RX3i redundancy communication link
  • Front Panel Module ID: RMX128
  • Front Panel Status Indicators: OK, LINK OK, SIG DET, OWN DATA
  • Redundancy Status Indicators: Local Ready, Local Active, Remote Ready, Remote Active
  • Front Panel Control: Role Switch 0 / 1
  • Typical Application: RX3i Hot Standby redundancy systems and deterministic reflective memory data sharing

Interchangeable / Replacement Part Numbers

  • IC695RMX128-EG
  • IC695RMX128EG

No alternate revision suffixes are listed as direct interchangeable replacements for this item. If a customer requires IC695RMX128-EG, the replacement supplied should be IC695RMX128-EG unless the customer approves a different revision.

Revision / Suffix Notice

This listing is specifically for revision IC695RMX128-EG.

Other revision suffixes such as IC695RMX128-AA, IC695RMX128-AB, IC695RMX128-AC, IC695RMX128-AD, IC695RMX128-AE, IC695RMX128-BE, and other later revisions may exist, but they are not listed here as automatic substitutes.

Revision suffixes may reflect hardware revision, firmware revision, manufacturing changes, agency certification labeling, branding updates, or customer-specific validation requirements. In industrial automation and redundancy systems, the exact revision may be important.

✅ Confirmed Compatibility

✔️ PACSystems RX3i Main Rack Systems: RX3i systems using a compatible RX3i Universal Backplane / PCI backplane configuration
✔️ PACSystems RX3i Hot Standby Redundancy Systems: RX3i redundancy systems using IC695RMX128-EG as the redundancy communication link between primary and secondary controller systems
✔️ RX3i Redundancy Link Applications: Systems requiring a dedicated RMX module pair for CPU redundancy communication over multi mode fiber
✔️ RX3i Reflective Memory Network Applications: Supported reflective memory systems using IC695RMX128 modules for deterministic data sharing between compatible nodes
✔️ Multi Mode Fiber RMX128 Installations: Existing systems requiring the IC695RMX128 multi mode fiber version with LC-style TX/RX fiber connections
✔️ GE Fanuc / Emerson PACSystems RX3i Automation Platforms: Compatible RX3i automation environments where IC695RMX128-EG is specified in the system design, spare parts list, or maintenance documentation

Please verify the exact part number, revision suffix, firmware requirements, fiber type, and system configuration before ordering. Compatibility may vary depending on the installed CPU, backplane, firmware level, redundancy configuration, and site validation requirements.

☑️ Key Features

☑️ Provides 128 MB of reflective memory for PACSystems RX3i applications
☑️ Designed for RX3i Hot Standby redundancy and high-speed memory exchange communication
☑️ Uses multi mode fiber for high-speed deterministic data transfer
☑️ Dual LC-style TX/RX fiber ports for reflective memory ring or redundancy link connections
☑️ Supports operation as a reflective memory network node or as a dedicated redundancy communication link
☑️ Front-panel LEDs provide quick visibility for module status, link status, signal detection, and data activity
☑️ Local and remote redundancy indicators help identify controller-side readiness and active status
☑️ Single-slot RX3i form factor for installation in compatible RX3i rack systems
☑️ Suitable for maintaining or replacing IC695RMX128-EG modules in existing RX3i redundancy systems
☑️ Designed for industrial automation systems requiring fast synchronized data sharing

⚙️ Fit Notes

  • This listing is for IC695RMX128-EG only.
  • Match the revision suffix before ordering if your system requires an exact replacement.
  • Do not substitute IC695RMX128-EG for another suffix unless the customer or site engineer approves the revision change.
  • Confirm your system requires the multi mode fiber version. IC695RMX228 is the single-mode fiber version and is not the same module.
  • This module requires a compatible RX3i Universal Backplane / PCI backplane environment.
  • For Hot Standby redundancy systems, matching RMX modules may be required on both the primary and secondary controller sides.
  • When used as a redundancy communication link, the RMX module should not also be used as a general-purpose Memory Xchange network node.
  • Verify CPU compatibility, firmware requirements, fiber cable type, node configuration, and Proficy Machine Edition project settings before installation.
  • Industrial control systems may require exact revision matching due to plant standards, validated configurations, safety documentation, or maintenance procedures.
Compatible Models

Product Reviews

Purchased This Product Before? Write a Review

Free Ground Shipping

On Orders $99 or more

Money Back Guarantee

Not Satisfied? Return it!

Hassle-Free Returns

Shop with confidence

Need Assistance?

Call 786-449-6211 or Email Us