false

M391B5773BH1-YH9 - 2GB 1Rx8 PC3L-10600E DDR3L-1333 ECC Unbuffered 240-Pin UDIMM Memory for Workstations and Servers

Item#: M391B5773BH1-YH9 Condition: Refurbished ⭐ High-Volume Order Fulfillment: Large Quantities Available! ✔️: Includes CPU Medics Warranty!
On Sale $25.00
Retail $49.00
In Stock
Usually Ships In 2-3 Business Days
Money Back Guarantee
Not satisfied? Send it back!
Request a quote below to see price
REQUEST A QUOTE
M391B5773BH1-YH9 - 2GB 1Rx8 PC3L-10600E DDR3L-1333 ECC Unbuffered 240-Pin UDIMM Memory for Workstations and Servers

M391B5773BH1-YH9 - 2GB 1Rx8 PC3L-10600E DDR3L-1333 ECC Unbuffered 240-Pin UDIMM Memory for Workstations and Servers

Item#: M391B5773BH1-YH9

* Indicates a required field

  • Product Description
  • Compatible Models
  • Warranty & Returns
Product Description

2GB 1Rx8 PC3L-10600E DDR3L-1333 ECC Unbuffered 240-Pin UDIMM Memory for Workstations and Servers

2GB 1Rx8 PC3L-10600E memory for compatible servers, workstations, desktop computers, and motherboards that use 240-pin DDR3 ECC unbuffered DIMMs.

This memory is rated at 1333 MT/s with CL9 timing and uses a single-rank x8 layout with 2Gb DRAM devices. It supports 1.35V DDR3L operation and can operate at 1.5V in compatible DDR3 systems.

⭐ Volume Orders Welcome

We have quantities available and welcome bulk orders. Simply place your order online for the quantity you need, and we’ll take care of the rest.

Package Includes

  • 1 × 2GB 1Rx8 PC3L-10600E DDR3L ECC unbuffered memory module

Technical Specifications

  • Capacity: 2GB per module
  • Memory type: DDR3L SDRAM
  • Speed grade: PC3L-10600E / DDR3L-1333
  • Rated speed: 1333 MT/s
  • CAS latency: CL9
  • Rank and device width: 1Rx8, single rank using x8 DRAM devices
  • Module organization: 256M × 72, using nine 2Gb x8 DRAM devices
  • Error correction: ECC
  • Module type: Unbuffered UDIMM
  • Form factor: 240-pin DIMM
  • Voltage: 1.35V nominal, with 1.5V operation on supported DDR3 platforms
  • Module height: Standard-height and very low profile versions are listed below. Match the height required by your chassis.

Interchangeable / Replacement Part Numbers

Standard-height module references

HMT325U7AFR8A-H9, HMT325U7BFR8A-H9, HMT325U7BFR8A-H9T0, HMT325U7CFR8A-H9, HMT325U7CFR8A-H9T0, HMT325U7EFR8A-H9, HMT325U7EFR8A-H9T0, M391B5773BH1-YH9, M391B5773CH0-YH9, M391B5773CH0-YH900, M391B5773DH0-YH9, MT9KSF25672AZ-1G4, MT9KSF25672AZ-1G4D1, MT9KSF25672AZ-1G4D1ZE, MT9KSF25672AZ-1G4K1, MT9KSF25672AZ-1G4K1ZE, MT9KSF25672AZ-1G4K1ZG, MT9KSF25672AZ-1G4M1, MT9KSF25672AZ-1G4M1ZE, MT9KSF25672AZ-1G4M1ZF, MT9KSF25672AZ-1G4M1ZG
NT2GC72C89B2NF-CG, NT2GC72C89G0NF-CG, ACT2GHU72C8H1333S-LV

System option, spare, and assembly references

647905-B21, 647905-S21, 647656-071, 664694-001, 49Y1403, 49Y1421, 47J0142, DM0KY, 0DM0KY, SNPDM0KYC/2G, SNPDM0KYC/2GWS

References that require a label check

637458-571, N8402-122F. For these references, verify that the module itself is marked 2GB 1Rx8 PC3L-10600E.

Very low profile module references

M390B5773DH0-YH9, KVR13LE9L/2, MT9KDF25672AZ-1G4. These modules share the same electrical specifications and use the shorter VLP form factor.

✅ Confirmed Compatibility

Compatibility applies to configurations that support 2GB DDR3 ECC UDIMMs. The installed processor, BIOS, and slot population determine operating speed and memory limits.

Servers and storage systems

✔️ HPE ProLiant Gen8 rack servers DL160 Gen8, DL320e Gen8, DL320e Gen8 v2, DL360e Gen8, DL360p Gen8, DL380e Gen8, DL380p Gen8
✔️ HPE ProLiant Gen8 tower and MicroServer ML310e Gen8, ML310e Gen8 v2, ML350e Gen8, ML350e Gen8 v2, ML350p Gen8, MicroServer Gen8
✔️ HPE ProLiant Gen8 blade and scale-out systems BL420c Gen8, BL460c Gen8, WS460c Gen8, SL230s Gen8, SL250s Gen8, SL270s Gen8
✔️ HP ProLiant G6 and G7 DL120 G6, DL120 G7, DL160 G6, DL180 G6, DL320 G6, DL360 G6, DL360 G7, DL380 G6, DL380 G7, ML110 G6, ML110 G7, ML150 G6, ML350 G6, ML370 G6, MicroServer N36L, N40L, N54L
✔️ PowerEdge rack servers R210, R210 II, R310, R320, R410, R415, R420, R510, R515, R520, R610, R620, R710, R715, R720, R720xd, R815
✔️ PowerEdge tower servers T20, T110, T110 II, T310, T320, T410, T420, T610, T620, T710
✔️ PowerEdge modular servers M420, M520, M610, M610x, M620, M710, and documented M520 and M620 configurations for PowerEdge VRTX
✔️ PowerVault NX200, NX3000, NX3200
✔️ System x M3 x3200 M3, x3250 M3, x3400 M3, x3500 M3, x3550 M3, x3650 M3
✔️ and System x M4 x3100 M4, x3250 M4, x3300 M4, x3500 M4, System x iDataPlex dx360 M4, Flex System x220 Compute Node
✔️ ThinkServer RS140, RS210, TS130, TS140, TS200, TS200v, TS430, TS440
✔️ Intel server systems SR1630GP, SR1630GPRX, SR1630HGP, SR1630HGPRX, SR1695GPRX, R1304BT family, P4304BT family, P4308RPLSHDR, R1208JP4GS, R1208JP4OC, R1208JP4TC, R1304JP4GS, R1304JP4OC, R1304JP4TC, P4000CP systems with an S2600CP board, MFSYS25V2 with the MFS2600KI compute module
✔️ Supermicro SuperServer 1016i-UF, 5016I-MR, 5016I-MRF, 5016I-URF, 5017C-MF, 5017C-MTF, 5017C-MTRF, 5018D-MF, 5018D-MTF, 5018D-MTRF, 5018D-MTLN4F, 5038D-I, 5018A-MHN4, 5018A-MLHN4, 5018A-MLTN4, 5018A-TN7B
✔️ ASUS server systems TS100-E6, TS100-E7, TS300-E7, RS100-E7, RS300-E7, RS300-H8-PS12, RS500-E6, RS520-E6, RS704D-E6, RS720-E6, RS724Q-E6, RS920-E7/RS8, RS926-E7/RS8
✔️ GIGABYTE server systems GS-R12PE1, GS-R22PE, GS-R12P4S
✔️ TYAN server systems YR292-B5538-X4, GN70-B7056
✔️ Fujitsu PRIMERGY TX100 S2, TX100 S3, TX100 S3p, TX120 S3, TX120 S3p, TX140 S1, TX140 S1p, TX150 S7, RX100 S6, RX100 S7, RX100 S7p
✔️ Acer Altos T110 F2, T110 F3 DDR3 models, G540 M2, R520 M2, R720 M2
✔️ NEC Express5800 B110d
✔️ Seagate Business Storage 8-Bay Rackmount NAS

Workstations and desktop computers

✔️ HP Z-series workstations Z200, Z200 SFF, Z210, Z210 SFF, Z220, Z220 SFF, Z230, Z230 SFF, Z400, Z420, Z600, Z620, Z800, Z820, original Z1
✔️ Precision workstations T1600, T1650, T1700 Mini Tower, T1700 SFF, T3500, T3600, T5500, T5600, T7500, R5500
✔️ ThinkStation workstations E20, E30, E31 Tower and SFF, E32 Tower and SFF, S20, S30, C20, C20x, C30, D20, D30, P300 Tower and SFF with ECC-capable processor configurations
✔️ Apple Mac Pro towers Early 2009 (MacPro4,1), Mid 2010 (MacPro5,1), Mid 2012 (MacPro5,1). The installed processor determines operating speed.
✔️ Sun workstation Ultra 27

Motherboards

✔️ Intel S3420 and S1200 boards S3420GPLC, S3420GPLX, S3420GPLXSASM, S3420GPRX, S3420GPV, S1200BTL, S1200BTLR, S1200BTLRM, S1200BTS, S1200BTSR, S1200KP, S1200KPR, S1200V3RPL, S1200V3RPO, S1200V3RPS
✔️ Intel S1400, S1600, and S2400 boards S1400FP2, S1400FP2IOC, S1400FP4, S1400FP4IOC, S1400SP4, S1600JP4, S2400GP2, S2400SC2, S2400SC2IOC4
✔️ Intel S2600 and workstation boards S2600CP2, S2600CP2IOC, S2600CP2J, S2600CP4, S2600CP4IOC, S2600CO2, S2600CO4, S2600COE, S2600GZ, S2600IP, S2600JF, W2600CR, S5500HCV, S5520HC, S5520HCR, S5520HCT, S5520SC, S5520UR
✔️ Supermicro X8 boards X8SIA, X8SIA-F, X8SIE, X8SIE-F, X8SIE-LN4, X8SIE-LN4F, X8SI6-F, X8SIL, X8SIL-F, X8SIT-F, X8SIU-F, X8STi, X8STi-F, X8STi-3F, X8STi-LN4
✔️ Supermicro X9 boards X9SCA, X9SCA-F, X9SCi-LN4, X9SCi-LN4F, X9SCL, X9SCL-F, X9SCL+-F, X9SCM, X9SCM-F, X9SCM-iiF, X9DAi, X9SRA, X9SRE, X9SRE-F, X9SRi, X9SRi-F, X9SRL, X9SRL-F, X9SRH-7F, X9SRH-7TF
✔️ Supermicro X10 and Atom boards X10SLA-F, X10SL7-F, X10SLH-F, X10SLL, X10SLL-F, X10SLL-S, X10SLL-SF, X10SLM-F, X10SLM+-F, X10SLM+-LN4F, A1SAM-2550F, A1SRM-2558F, A1SRM-2758F
✔️ ASUS P-series server and workstation boards P7F-X, P8B-X, P8B-M, P8B-MX, P8B-E/2L, P8B-E/4L, P8C WS, P9D-C/4L, P9D-C/SAS/4L, P9D-E/4L, P9D-M, P9D-MH, P9D WS, P9X79 WS, P9X79-E WS
✔️ ASUS Z-series server and workstation boards Z8PE-D18, Z8PH-D12 SE/QDR, Z8NH-D12, Z8NH-D12 SE/NM, Z8NR-D12, Z9NA-D6, Z9NA-D6C, Z9PA-D8, Z9PA-D8C, Z9PA-U8, Z9PE-D8 WS, Z9PE-D16, Z9PE-D16/10G, Z9PX-Q32
✔️ ASUS AM3 and AM3+ desktop boards with an ECC-capable processor M5A78L-M LX V2, M5A78L-M LE/USB3, M5A97 LE R2.0, M5A99FX PRO R2.0
✔️ ASRock Rack boards C226 WS, C226 WS+, C226M WS, E3C224, E3C224D2I, E3C224D4I-14S, E3C226D2I, C2550D4I, C2750D4I, C2750D4I+
✔️ GIGABYTE server boards GA-6FASV1, GA-6LISL, GA-6PXSV2, GA-6PXSV4, GA-6UASV3
✔️ TYAN server boards S5502, S5510, S5512, S5512-HE, S5530, S5532, S5533, S7010, S7012, S7025, S7050, S7053, S7055, S7056
✔️ Advantech industrial boards ASMB-781, ASMB-782, ASMB-784
✔️ Fujitsu server boards D2779, D3049

☑️ Key Features

  • ECC error correction helps protect data integrity on systems with ECC enabled.
  • Single-rank x8 configuration matches platforms specified for 2GB 1Rx8 DDR3 ECC UDIMMs.
  • Low-voltage DDR3L design supports 1.35V operation and compatibility with supported 1.5V DDR3 systems.
  • DDR3-1333 CL9 rating suits legacy server and workstation memory configurations.

⚙️ Fit Notes

✓ Match the module label. Look for 2GB, 1Rx8, and PC3L-10600E when replacing an existing module.
✓ Select the correct memory type. Use a 240-pin DDR3 ECC UDIMM slot. Keep ECC UDIMMs separate from registered RDIMMs, load-reduced LRDIMMs, and non-ECC DIMMs.
✓ Check chassis clearance. Use a VLP reference if the original module is very low profile or the chassis requires it.
✓ Follow the system’s slot population rules. Match the installed configuration where required and use the slots assigned to the installed processor.
✓ Check operating speed. The system may run the memory at 1066 MT/s or another supported lower speed based on the processor and DIMM population.

Compatible Models

Product Reviews

Purchased This Product Before? Write a Review

Free Ground Shipping

On Orders $99 or more

Money Back Guarantee

Not Satisfied? Return it!

Hassle-Free Returns

Shop with confidence

Need Assistance?

Call 786-449-6211 or Email Us